Cooling

Various systems for cooling of technologic media with really top performances.

Products by supplier:
GC

GC

Cooling capacity of coolers GC for cooling the process water is in the range from 3.7 to 135 kW. Coolers are delivered either with air or water condensation, with centrifugal or axial fans. Standard delivery includes pump and reservoir for direct connection to the circuit, but versions E and P can be supplied independently without reservoir and without pump.

MCHILL – TCHILL

Cooling capacity of coolers process water MCHILL/TCHILL is in the range from 4,6 a 42 kW. Water cooled units provide a sophisticated temperature control to -15 ° C with an accuracy of 0.2 ° C as well as high flow and high pressure pump.

AXevo

AXevo – AXevo/FC

AXevo is a medium cooler of process water (cooling liquid from 28,7 to 224 kW), cooled by water or air, which serves to cool a process water. The main characteristics of the series is efficiency, flexibility and top performance. The FC version provides the economic operation thanks to the „free-cooling“ function – cooling without a compressor during winter months.

NAX

NAX

Cooling capacity of coolers process water NAX is in the range from 172 to 942 kW. Coolers are delivered with air and axial ventilators. Standard delivery includes pump and reservoir, but can be adjusted according to customer needs and applications.

TFC

TFC – Total free cooling

Cooling capacity of coolers process water TFC with embedded free quarto-cooler is between 168 and 701 kW. The design of these units is considerate to the environment through the use of CFC-free technology.

ADY-NAX

DY-NAX – ADY-NAX

Units DY-NAX are air cooled cooler of process water, which can be placed outdoors and unfunded. Version ADY-NAX (adiabatic cooler) combines the structural and functional features of standard models with efficient energy consumption even at high temperatures. The cooling capacity is between 115 and 691 kW.

DCooler_smaller

Dcooler

Modular non-compressor cooler of process water, cooling capacity from 63 to 920 kW. Ecological alternative to cooling towers. The structure of units and its characteristics are very similar properties ADcooler without the adiabatic system.

ADcooler

ADcooler

Adiabatic non-compressor cooling of process water, cooling capacity from 82 to 1220 kW. ADcooler combines energy saving with efficiency of adiabatic system. Ecological alternative to cooling towers. Video

GRP

GRP

The group of pumps GRP provide cooling water flow in circuit between 12.5 and 220 m³ / h. In metal frame is placed a water reservoir, pump and electrical panel, controling the entire system. The pumps are centrifugal, high pressure type. Pumps with GRP tanks are designed especially for coolers type DY-NAX, ADY-NAX, ADcooler, Dcooler.